Chapter 26 — The verification plan
Chapter 24 described the outcomes of recording verification, chapter 25 the way in which each element of a boundary appears. The verification plan relates them: it indicates with which instruments a boundary is recorded, with what resolution, and which guarantees each instrument observes.
bcdd reads the verification plan, checks its names and calculates which guarantees each instrument observes. No
program described in this manual executes a verification plan or recording verification.
The verification plan
A recording instrument is a tool that records what happens at a boundary through the concrete forms of the boundary: a recorder connected to a terminal, a sensor, a camera, a program that records the messages of a network. A test tool built into the system, such as a test option of a program, is also a recording instrument; the way to activate it is a concrete form. An instrument observes what it records: an element that no instrument records is not observed.
The resolution of an instrument is the smallest time interval that the instrument distinguishes.
The verification plan of a boundary is written in a VERIFICATION … END block, whose header names the bound CSC
with its version. It contains:
- the recording instruments, each with the elements of the CSC that it observes and its resolution;
- the scenarios written in concrete forms, each with the scenario of the CSC that it translates.
bcdd calculates the guarantees that each instrument observes and those that no instrument observes, which remain not executed. The verification plan does not
contain guarantees and does not contain outcomes: it establishes how the recordings on which the guarantees are
verified are collected.
The recording instruments of the light
For the staircase light two instruments are used: a light sensor in front of the lamp, with a resolution of one
millisecond, and a camera that films the button and the lamp together at 25 frames per second, with a
resolution of 40 ms. A recorder connected between terminal 3 and the common terminal observes instead the boundary
Comando, which has its own verification plan. The verification plan is in a file of its own, PianoLuce.csc:
-- The verification plan of the staircase light.
VERIFICATION UsoLuce VERSION 0.3
MEANS sensore OBSERVES modo, avviso RESOLUTION 1 ms
MEANS telecamera OBSERVES premuto, modo RESOLUTION 40 ms
SCENARIO s1-scale TRANSLATES s1
@0 s VERBAL "a finger presses the key of the wall button; the lamp switches on"
@85 s VERBAL "the lamp switches off for 0.3 s and switches on again"
@90 s VERBAL "the lamp switches off"
@100 s VERBAL "a finger presses the key again; the lamp switches on"
END
VERIFICATION Comando VERSION 0.1
MEANS registratore OBSERVES accendi RESOLUTION 1 ms USING filo
END
A MEANS line declares an instrument: the name, the elements of the bound CSC that it observes (OBSERVES) and the
resolution (RESOLUTION), a duration with a unit. With USING the instrument names the BINDING through which it observes:
the recorder reads the accendi events in the form of the wired button, the block AS filo of chapter 25. The sensor
records whether the lamp is on or off, and the concrete forms of chapter 25 establish how to read the
recording: a lamp off for 0.3 s and then on again is an avviso, a lamp off is
modo = spenta. The specification leaves to whoever implements the system the way of obtaining traces from recordings.
The guarantees observed by each instrument
A formal guarantee that cites an element that is not recorded has the outcome not executed (chapter 24). bcdd calculates,
for each instrument, the formal guarantees and assumptions that the instrument observes in full: a line is observed by an
instrument if every state, event and request it names is among its OBSERVES elements. The lines that no instrument
observes in full are not executed. Verbal lines do not take part in this calculation: they are verified by judgement or by inspection.
$ bcdd check PianoLuce.csc
bcdd check PianoLuce.csc
lines: 15 (recognised 12, comments 1, blank 2, unrecognised 0)
blocks: 2
line 3: VERIFICATION UsoLuce VERSION 0.3
line 3: CSC UsoLuce in UsoLuce.csc at line 4: VERSION 0.3, STATUS HYPOTHESIS, no errors
line 13: VERIFICATION Comando VERSION 0.1
line 13: CSC Comando in Comando.csc at line 3: VERSION 0.1, STATUS HYPOTHESIS, no errors
line 14: USING filo in Comando.csc at line 13
1. ERRORS: 0
2. DEGREE OF THE CONTRACTUAL LINES
verbal: 0
formal: 0
declared extension: 0
unrecognised: 0
3. UNDECIDED: 0
4. PENDING APPROVAL, NOT CONTRACT: 0
5. UNRECOGNISED LINES: 0
6. UNDECLARED TYPES: 0
7. CSCs NAMED BUT NOT CHECKED: 0
13. VERIFICATION PLAN COVERAGE: 4
line 3: VERIFICATION UsoLuce VERSION 0.3
sensore (line 4): g2, g8
telecamera (line 5): g1, g2, g2a, g7a, g9
not executed: g3a, g4a, g4b, g10
line 13: VERIFICATION Comando VERSION 0.1
registratore (line 14): none
not executed: none
outcome: no errors
Section 13, VERIFICATION PLAN COVERAGE, shows the calculation:
- the sensor observes
g2andg8, which concern only the mode and the warning; - the camera observes
g1,g2,g2a,g7aandg9, which concern the press and the mode; g3aconcerns the press, the mode and the warning, and no instrument observes all three by itself;g4a,g4bandg10concern cleaning requests, which no instrument records. These guarantees are not executed.
The count of the section is the number of guarantees not executed. The section appears only when the file
contains at least one VERIFICATION block, and it is not an error. The list of observed guarantees is not written in the file: bcdd derives it
each time from the OBSERVES lines.
Section 13 also lists the guarantees not executed. A verification report that omitted them would suggest that they have been verified.
With the sensor alone, without the camera, the press is not recorded by any instrument:
13. VERIFICATION PLAN COVERAGE: 8
line 3: VERIFICATION UsoLuce VERSION 0.3
sensore (line 4): g2, g8
not executed: g1, g2a, g3a, g4a, g4b, g7a, g9, g10
line 12: VERIFICATION Comando VERSION 0.1
registratore (line 13): none
not executed: none
The recorder detects the accendi events, which follow the presses, but not the presses. Deriving a press from
an accendi would require guarantee pu1 of the button (chapter 13), and a guarantee does not replace
an observation: for this reason g1 remains not executed as long as no instrument records premuto.
The resolution
The resolution limits the scope of an outcome. “Satisfied on the trace” applies with the declared resolution
of the instrument (chapter 24): for g2a, which admits a switch-off between 85 and 95 seconds after the last press,
a resolution of 40 ms is sufficient. For g1, which requires the light on in the same step as the press,
the outcome depends on the criterion by which, starting from the recording, it is established that the two facts fall in
the same step. Two
facts recorded by different instruments are considered to be in distinct steps only if their distance exceeds the
coarser resolution of the two instruments. Otherwise the temporal relation is indeterminate: it is not established
whether the facts are in the same step or in distinct steps. If an instrument with a resolution of 40 ms records the
press at 10.000 s and another records the light on at 10.015 s, the two facts are not distinguished and g1 is inconclusive in
that step; if the light comes on at 10.200 s, g1 is violated.
An instrument that distinguishes only intervals longer than the duration of a concrete form does not observe it. A
light sensor that detects the state of the lamp once per second may fail to detect a 0.3 s flash:
in the verification plan avviso does not figure among the elements that sensor observes, and g8 has the outcome “not
executed”. Declaring avviso among the observed elements would give g8 the outcome “satisfied on the
trace” even on a recording in which a warning slipped between two readings. bcdd does not compare the
resolution with the concrete forms: the choice of the OBSERVES elements remains with whoever writes the plan.
Scenarios in concrete forms
A translated scenario rewrites a scenario of the CSC in the concrete forms: SCENARIO s1-scale TRANSLATES s1
translates scenario s1 of UsoLuce. Its steps have the times of the scenario it translates and contain assertions in
words (VERBAL). It has neither GIVEN nor EXPECT: its expected outcome is that of the scenario it translates. If the bound
CSC does not have the named scenario, bcdd reports error E31.
Some facts that arise in the concrete forms do not appear in the scenario of the CSC, and on them an
implementation can behave incorrectly. A 30 ms contact on terminal 3, for example, is not an accendi (chapter
25), and it does not appear in the scenario of the CSC Comando. The verification plan of Comando can then contain a translated
scenario: “contact closed for 30 ms at instant 0 s, contact closed for 80 ms at instant 1 s”. This scenario translates a
scenario of Comando with a single accendi, that of the second contact. A lamp that comes on already at the first
contact treats as accendi a contact that is not one: the translated scenario allows this to be detected, whereas the scenario
of the CSC Comando, on its own, does not contain the 30 ms contact.
Summary
- The verification plan (
VERIFICATION Csc VERSION v … END) indicates the recording instruments of a boundary and the scenarios in concrete forms. It contains neither guarantees nor outcomes, and it is not approved. - A recording instrument (
MEANS name OBSERVES elements RESOLUTION duration [USING forms]) observes a boundary through the concrete forms of the boundary; its resolution is the smallest time interval that it distinguishes. bcddcalculates in section 13 the formal guarantees that each instrument observes in full and those not executed; a guarantee does not replace an observation.- “Satisfied on the trace” applies with the resolution of the instrument; an instrument that distinguishes only intervals longer than the duration of a concrete form does not observe it.
- A translated scenario (
SCENARIO id TRANSLATES scenario) rewrites a scenario of the CSC in the concrete forms.
Special cases
A verification plan is not approved. For a STATUS line in a VERIFICATION block bcdd reports error E39; in the same
file, for a translated scenario that names a scenario absent from the CSC it reports error E31:
1. ERRORS: 2
line 4: [E39] STATUS cannot appear in a VERIFICATION: a verification plan is not approved
line 7: [E31] TRANSLATES names a scenario that CSC UsoLuce VERSION 0.3 does not have: s9
bcdd ratify refuses a file that contains only verification plans:
$ bcdd ratify PianoLuce.csc --all D-22
bcdd ratify: the file contains no block to approve: a VERIFICATION is not approved
An instrument connected inside a part. A recorder connected to the terminals that supply the bulb, inside the lamp, records the implementation and not a boundary: no guarantee can be verified on that recording. The verification plan associates each instrument with a boundary, through the concrete forms of the boundary.
A verbal guarantee and the recorder. Guarantee c1 of Comando, “at least 0.2 s pass between two accendi”,
is checked by inspection on the “recorded commands”: the recording of the recorder is the material
of the inspection. The outcome remains a judgement, “conforming by judgement” or “non-conforming by judgement”, with who
judged, and is reported separately from the outcomes of formulas (chapter 24). For this reason the recorder observes
no formal guarantee of Comando, and section 13 shows it with none.
Several recordings of the same guarantee. A guarantee satisfied on ten recordings remains satisfied on those ten traces, with the resolution of the instruments used: the number of recordings does not turn the outcome into a certainty about the situations not observed.