Chapter 22 — Time in formulas
The detail g2a states that the light switches off 90 seconds after the last press, with a 5-second
tolerance. The keywords of chapter 21 are not enough to express it: they establish in which steps a condition
holds, but do not measure the time that passes between two steps. This chapter introduces the time limit, which
measures the time that follows a step. It then introduces the forms that concern what has already occurred in the
trace: the elapsed time, the count and the previous value. Finally it introduces repeating scenarios.
Within a certain time: WITHIN
The time limit is written with WITHIN followed by a duration, and is added to EVENTUALLY or to
WHENEVER:
| Form | Meaning |
|---|---|
EVENTUALLY p WITHIN d |
p holds in some step within d of the start of the scope |
WHENEVER p THEN q WITHIN d |
in every step in which p holds, q must hold within d of the trigger step, the step itself included |
The duration always has a unit, s or ms. With WITHIN the guarantee has a deadline: if the consequence does not hold
within the duration, the guarantee is violated. WITHIN and AT ONCE do not go in the same guarantee (error E27).
For a formula without WHILE the start of the scope is the first step of the trace. With WHILE the scope may
consist of several separate stretches of the trace: each stretch is a scope of its own, and the duration runs
from the start of each stretch. WHILE modo = in_pulizia: EVENTUALLY avviso WITHIN 5 s therefore requires a
warning in every cleaning stretch, within 5 s of its start. A stretch that ends without a warning before
5 s have elapsed violates the guarantee.
In the staircase light CSC a detail of guarantee g4 is added: a cleaning request receives a
response within one second.
GUARANTEE g4a DETAILS g4: WHENEVER requested(Pulizie) THEN accepted(Pulizie) OR rejected(Pulizie) WITHIN 1 s
The elapsed time: TIME SINCE
TIME SINCE e measures the elapsed time since the last step in which the event e occurred.
TIME SINCE premuto <= 95 s holds in the steps in which the last press dates back no more than 95 seconds.
In the very step in which e occurs, TIME SINCE e is 0. Before e has occurred at least once its
value is infinite: TIME SINCE premuto > 90 s is true even if nobody has ever pressed, and
TIME SINCE premuto <= 95 s is false. Infinity is used only in comparisons, not in calculations. To exclude the
case in which the event has never occurred, a condition such as TIME SINCE premuto >= 85 s is combined with the
count COUNT(premuto) > 0, which holds only if the event has already occurred.
The count: COUNT
The count COUNT(e) is the number of steps in which the event e has occurred, from the start of the trace
up to and including the step considered. COUNT(premuto) > 0 holds from the step of the first press onwards.
COUNT(e SINCE f) counts only the steps with e that follow the last step in which the event f occurred.
COUNT(premuto SINCE avviso) = 0 holds in the steps in which nobody has pressed since the last warning.
COUNT(e) IN LAST d counts only the steps in which e occurred in the interval of duration d that ends with
the step considered. The step considered is included; the step exactly d away is not. In the CSC
Comando of chapter 13 the button provides the command accendi. Its guarantee c1 establishes that at least
0.2 seconds pass between two commands. Written as a formula, the guarantee establishes that in every interval of
0.2 seconds no more than one command is issued:
GUARANTEE c1a DETAILS c1: ALWAYS COUNT(accendi) IN LAST 0.2 s <= 1
In formulas decimal numbers are written with a point. Two commands exactly 0.2 seconds apart satisfy the guarantee: when the second arrives, the first is already outside the interval.
The duration of IN LAST consists only of the first value that follows the keyword: a number with a unit, a name,
a call or an expression in parentheses. No operator of the table in chapter 21 extends it. The formula c1a
therefore reads (COUNT(accendi) IN LAST 0.2 s) <= 1. A calculated duration is written in parentheses:
COUNT(e) IN LAST (2 * d).
In the report the line c1a is formal:
1. ERRORS: 0
2. DEGREE OF THE CONTRACTUAL LINES
…
line 11: GUARANTEE c1a formal
The filter on events: WITH
An event with parameters can be filtered on the value of its parameters: e WITH c occurs in the steps in which e occurs
and its parameters satisfy the condition c. The same applies to the phases of a request, with the parameters
of the request. Guarantee g4 states that a cleaning request longer than two hours is rejected; the requested
duration is the parameter durata of the request Pulizie:
GUARANTEE g4b DETAILS g4: WHENEVER (requested(Pulizie) WITH durata > 7200 s) THEN rejected(Pulizie) WITHIN 1 s
Two hours are written 7200 s, because the only units are s and ms. The condition of WITH extends to
the end of the expression: for this reason the filtered event is written in parentheses when something else follows it, as
in TIME SINCE (premuto WITH dove = primo) > 5 s.
The previous value: PREV
The previous value PREV(x) is the value of the state x in the previous step. In the first step it is the
initial value declared with INITIAL.
PREV is needed because in a step a state has the value it takes after the events of the step (chapter 21). Guarantee
g7 states that during cleaning a press does not change the mode. The condition “during cleaning”
concerns the mode before the press:
GUARANTEE g7a DETAILS g7: WHENEVER premuto AND PREV(modo) = in_pulizia THEN modo = in_pulizia AT ONCE
Whenever premuto occurs and in the previous step the mode was in_pulizia, in the same step the mode
is still in_pulizia.
PREV also identifies the step in which a state changes value: PREV(modo) = accesa AND modo = spenta
holds in the step in which the light switches off.
The switch-off and the warning as formulas
The detail g2a becomes:
GUARANTEE g2a DETAILS g2 STATUS HYPOTHESIS: ALWAYS ((PREV(modo) = accesa AND modo = spenta) IMPLIES (COUNT(premuto) > 0 AND TIME SINCE premuto >= 85 s AND TIME SINCE premuto <= 95 s))
It reads: in every step in which the light passes from on to off, there has been at least one press and since the last one between 85 and 95 seconds have elapsed. The 5-second tolerance is expressed by the two limits.
Three observations on the formula:
- reset of the time:
TIME SINCE premutomeasures the time since the last press, so the formula also expresses the content ofg2b, namely that a new press restarts the time from the beginning.g2bremains in the CSC, approved, and does not change. Its approved text keeps the word “count”, which refers to the measured time and not toCOUNT; - cleaning: the switch-off at the end of cleaning is a passage from
in_puliziatospenta, not fromaccesatospenta, and the formula does not concern it; - approval status:
g2ahad its ownSTATUS RATIFIED BY D-12; since the text changes, the guarantee returns to pending approval, withSTATUS HYPOTHESIS(chapter 10).
In scenario s2 the light switches off at instant 30: in step @30 s the formula requires at least 85 seconds
since the last press, and 30 have elapsed. The scenario violates g2a, and is therefore rejected, as its
line EXPECT REJECTED declares.
Guarantee g3, “shortly before switching off, the light gives a warning”, receives a formal detail:
GUARANTEE g3a DETAILS g3: ALWAYS ((PREV(modo) = accesa AND modo = spenta) IMPLIES (COUNT(avviso) > 0 AND COUNT(premuto SINCE avviso) = 0))
In every step in which the light switches off there has been at least one warning, and nobody has pressed after the last warning.
A press after the warning, therefore, prevents the announced switch-off. How long before the switch-off the warning
must arrive is not expressed by the detail and remains in the text in words of g3.
Repeating scenarios: REPEAT
A scenario can end with steps that repeat. The REPEAT line stands among the steps and applies until the end of the
scenario: the steps that follow it repeat at intervals of duration d.
| Form | Meaning |
|---|---|
REPEAT m..n EVERY d |
the steps that follow repeat from m to n times |
REPEAT FOREVER EVERY d |
the steps that follow repeat without end |
Each repetition begins d after the previous one, and the times @t of the repeated steps are measured from the
start of the repetition. In the following scenario someone climbing slowly presses the button every 60 seconds,
from one to five times, and the light is on after every press:
SCENARIO s5 EXPECT ADMITTED
REPEAT 1..5 EVERY 60 s
@0 s premuto modo = accesa
The scenario is equivalent to five scenarios, with one, two, three, four and five presses 60 seconds apart. bcdd
checks the form of the repetition and reports error E30 in the following cases:
- the scenario has two
REPEATlines; - the limits are not valid: the maximum must be at least 1 and not smaller than the minimum;
- after
REPEATthere is no step; - the times of the steps of the scenario are written without units;
- a repeated step has a time equal to or greater than the period.
The order of the times (error E12, chapter 9) is checked among the repeated steps, with the times measured from the start of the repetition.
The CSC and the report
The header comment becomes:
-- VERSION 0.3: g1, g2 and g2a written as formulas; g3a, g4a, g4b, g7a and g8 added. Pending approval.
The report shows eight formal lines:
$ bcdd check UsoLuce.csc
bcdd check UsoLuce.csc
lines: 57 (recognised 47, comments 5, blank 5, unrecognised 0)
blocks: 1
line 4: CSC UsoLuce VERSION 0.3, STATUS HYPOTHESIS
1. ERRORS: 0
2. DEGREE OF THE CONTRACTUAL LINES
verbal: 7
formal: 8
declared extension: 0
unrecognised: 0
line 16: GUARANTEE g1 formal
line 18: GUARANTEE g2 formal
line 20: GUARANTEE g2a formal
line 21: GUARANTEE g2b verbal
line 23: GUARANTEE g3 verbal
line 25: GUARANTEE g3a formal
line 26: GUARANTEE g4 verbal
line 28: GUARANTEE g4a formal
line 29: GUARANTEE g4b formal
line 30: GUARANTEE g5 verbal
line 32: GUARANTEE g6 verbal
line 34: GUARANTEE g7 verbal
line 36: GUARANTEE g7a formal
line 37: GUARANTEE g8 formal
line 38: ASSUME a1 verbal
…
14. TO BE JUDGED: 5
line 21: GUARANTEE g2b DETAILS g2: consistency between the line and the line that details it, one of the two in words
line 25: GUARANTEE g3a DETAILS g3: consistency between the line and the line that details it, one of the two in words
line 28: GUARANTEE g4a DETAILS g4: consistency between the line and the line that details it, one of the two in words
line 29: GUARANTEE g4b DETAILS g4: consistency between the line and the line that details it, one of the two in words
line 36: GUARANTEE g7a DETAILS g7: consistency between the line and the line that details it, one of the two in words
15. CHECKS NOT EXECUTED: 4
scenarios: lines 41, 46, 49, 51, 54
coverage of the triggers: lines 16, 18, 20, 25, 28, 29, 36, 37
consistency of assumptions and guarantees: lines 16, 18, 20, 25, 28, 29, 36, 37
consistency of the details: line 20
outcome: no errors
Section 15 now lists five scenarios, including s5, and eight formal lines for trigger coverage and for
consistency. The entry consistency of the details concerns g2a, which is a formal detail of a formula, g2. The consistency
between the two lines is a check that bcdd does not execute. The formal details of a guarantee in words, such as g3a,
g4a, g4b and g7a, are instead in section 14, because consistency with a line in words is judged.
Summary
WITHIN dadds a time limit toEVENTUALLYand toWHENEVER.TIME SINCE eis the elapsed time since the laste; it is 0 in the step ofeand infinite before the firste, so a comparison such as>= dis written together withCOUNT(e) > 0.COUNT(e)is the count of the steps withe;COUNT(e SINCE f)counts only those after the lastf;COUNT(e) IN LAST dcounts only those of the interval of durationdthat ends with the step considered, included, without the step exactlydaway.e WITH cfilters an event, or a phase of a request, on the value of its parameters.PREV(x)is the previous value of a state; in the first step it is the initial value.REPEAT m..n EVERY dandREPEAT FOREVER EVERY drepeat the steps that follow theREPEATline, up to the end of the scenario; every repeated step has a time smaller than the period.
Special cases
The value after the press. If in g7a modo = in_pulizia is written in place of
PREV(modo) = in_pulizia, the formula becomes: whenever there is a press and, after the press, the mode is
in_pulizia, the mode is in_pulizia. The formula is always satisfied and expresses no guarantee. Even a press
that takes the mode from in_pulizia to accesa, forbidden by g7, satisfies the formula. The form, names and
types are correct, and bcdd, which does not evaluate formulas,
does not detect the defect:
1. ERRORS: 0
2. DEGREE OF THE CONTRACTUAL LINES
…
line 36: GUARANTEE g7a formal
…
Light that never switches off. g2a is evaluated in the step of the switch-off. If in a trace the light
stays on until the end, g2a has no step in which to apply. That the switch-off does not happen is a
case covered by g2: “in a later step the light is off”.
Previous value in the first step. In the first step PREV(modo) is spenta, the value declared with
INITIAL. A press in the first step therefore has PREV(modo) = spenta, and g7a does not concern it.
Minutes and durations without a unit. The units of durations are only s and ms, as in scenarios and in
named constants: 90 seconds are written 90 s, and not 1.5 min. A number without a unit after WITHIN is not a
duration, and bcdd reports error E25, inconsistent type:
1. ERRORS: 1
line 28: [E25] inconsistent type: Duration needed, Integer found
A repeated step as long as the period. In scenario s5, a second repeated step @60 s would fall
at the same instant as the next repetition:
1. ERRORS: 1
line 57: [E30] the step @60 s is not shorter than the period of REPEAT: every repeated step has a time smaller than EVERY 60 s

